Pilot Plant Testing Units

Not all process streams are similar. In fact, a degree of variation exists in virtually every customer's application. New and specialized applications often require pilot testing or in-house tests to validate system designs. To overcome these process variations, we supply a unique testing service by eighter testing machine running at your site or at our facility. 



Model: BFM4040-1 


Designed Specification


Membrane available : Spiral type of 4040 

Membrane effective area: 3.8m2 

Maximum operation pressure: 6bar

Power: 5.5kw

Space cover: 1600*980*1363mm

Cycle volume: about 25L

Input voltage: 380V

Weight:100kgs


It is designed especially for specialty liquid clarification and concentration.





Model: RS4052-1 


Designed Specification



Membrane available size: Spiral type of 4040/2540

Membrane effective area: 2.7-8.0m2 

Maximum operation pressure: 25bar

Power: 5.2kw

Space cover: 1300*550*1516mm

Cycle volume: about 10L

Input voltage: 380V

Weight:120kgs